# Lead Operations Engineer, Data Center Facilities (SpaceXSI)

- **Company:** SpaceX
- **Location:** Memphis, TN, US (Not specified)
- **Salary:** Salary not disclosed
- **Contract:** Not specified
- **Posted:** 2026-11-19

## Job description

SpaceX was founded under the belief that a future where humanity is out exploring the stars is fundamentally more exciting than one where we are not. Today SpaceX is actively developing the technologies to make this possible, with the ultimate goal of enabling human life on Mars.
LEAD OPERATIONS ENGINEER, DATA CENTER FACILITIES (SPACEXSI)
RESPONSIBILITIES
Lead a team of operations and controls engineers responsible for facility automation, commissioning, and live-plant support across chillers, pumps, cooling towers, coolant distribution units, air handlers, heat rejection, and related plant equipment
Prioritize the team's design, construction, commissioning, failover, and live-event work, and define individual responsibilities
Architect, write, and debug PLC and controller code that is organized, structured, documented, maintainable, and reusable across chillers, pumps, cooling towers, coolant distribution units, air handlers, heat rejection, and related plant equipment
Implement lead/lag, staging, rotation, free-cooling, and liquid-cooling control strategies that hold capacity, efficiency, and redundancy (N+1 / 2N) as the cluster load changes
Keep the plant safe and reliable with fail-safe interlocks, emergency power off and transfer logic, and alarm philosophy that meets NEC, NFPA 70E, NFPA 75, and applicable life-safety requirements
Build clear HMI and control-room graphics so operators can see plant state, acknowledge alarms, trend equipment health, and troubleshoot without calling an engineer first
Integrate equipment controllers into the site BMS, EPMS, and historian so power, cooling, and environmental data are one operational picture
Design control panels and electrical interfaces compliant with NEC, NFPA, and UL 508A, including motor and VFD interfaces, safety circuits, and network architecture
Own the systems after go-live: alarm rationalization, loop tuning, sequence changes, outage support, and continuous improvement of uptime and energy performance
Build schedules and punch lists for controls scope and drive vendors, contractors, and internal teams to hit them during construction and live expansions
BASIC QUALIFICATIONS
Bachelor’s degree in electrical engineering, mechanical engineering, controls, mechatronics, or engineering discipline
2+ years of experience in industrial controls, building or plant automation, data center facilities, or related programming
1+ years of experience leading a team or technical project
PREFERRED SKILLS AND EXPERIENCE
Experience managing and developing engineers or a small technical team
Energized by fast, iterative design, construction, and commissioning on a live critical facility
Proven ability to turn a messy plant problem into a simple, reliable control solution
Clear written and verbal communication, including control narratives, sequences of operations, and recommendations across mechanical, electrical, and operations teams
Judgment to move quickly while protecting people and equipment around high voltage, stored energy, refrigerants, fuel systems, and high-pressure hydronics
Experience in data centers, power generation, district energy, industrial utilities, or other 24/7 process plants
Experience in at least one of the disciplines below, with a real interest in learning the others
Sizing and application of motors, VFDs, starters, valves, actuators, instrumentation, and circuit protection for pumps, fans, towers, and plant equipment
Design of fail-safe circuits using safety relays and safety controllers, including interlocks that must hold during a loss of power or a controls failure
Hands-on troubleshooting of industrial electrical systems with multimeters, oscilloscopes, and network diagnostics
Reading and producing schematics, panel layouts, riser diagrams, and one-line diagrams (EPLAN preferred)
Fieldbus and Ethernet plant networks: BACnet/IP, Modbus TCP, EtherNet/IP, Profinet, and OPC UA
Designing, building, and commissioning control panels and electromechanical systems with arc-flash, lockout/tagout, and construction-power constraints in mind
Working knowledge of NEC, NFPA 70E, UL 508A, and data center facility standards, with the ability to apply them to control design
PLC programming in structured text and ladder, preferably Rockwell (Studio 5000), Siemens TIA Portal, or Beckhoff TwinCAT
HMI, BMS, and SCADA development — Ignition, Niagara, or an equivalent platform — focused on fast navigation, meaningful alarms, trends, and equipment health
Industrial protocols used in critical facilities: BACnet/IP, Modbus TCP, OPC UA, MQTT, SNMP, EtherNet/IP, and Profinet
Applying control software to mechanical and electrical assemblies: sensors, VFDs, valves, and pump or fan systems, including a disciplined checkout before a system is allowed to carry load
Experience with EPMS, power metering, generator or ATS status, and historian or alarming tools used to operate a data center
ADDITIONAL REQUIREMENTS
Ability to work long hours, nights, and weekends when commissioning, failover testing, or a live plant event requires it
Willingness to work on site in the data center, including mechanical plants, electrical rooms, and the data halls, for checkout and troubleshooting
ITAR REQUIREMENTS
To conform to U.S. Government export regulations, applicant must be a (i) U.S. citizen or national, (ii) U.S. lawful, permanent resident (aka green card holder), (iii) Refugee under 8 U.S.C. § 1157, or (iv) Asylee under 8 U.S.C. § 1158, or be eligible to obtain the required authorizations from the U.S. Department of State. Learn more about the ITAR here .
SpaceX is an Equal Opportunity Employer; employment with SpaceX is governed on the basis of merit, competence and qualifications and will not be influenced in any manner by race, color, religion, gender, national origin/ethnicity, veteran status, disability status, age, sexual orientation, gender identity, marital status, mental or physical disability or any other legally protected status.
Applicants wishing to view a copy of SpaceX’s Affirmative Action Plan for veterans and individuals with disabilities, or applicants requiring reasonable accommodation to the application/interview process should reach out to EEOCompliance@spacex.com .

[Apply on the company site](https://www.joonow.com/en/job/lead-operations-engineer-data-center-facilities-spacexsi-memphis-tn-qpvyqpbwm4/apply)
